• Product details image
ASTM A214 Heat-Exchanger And Condenser Tube
  • ASTM A214
  • China
  • Stock
  • ASTM A214

ASTM A214/A214M Standard Specification for Electric-Resistance-Welded Carbon Steel Heat-Exchanger and Condenser Tube

ASTM A214 Heat-Exchanger And Condenser Tube

ASTM A214 Heat-Exchanger and Condenser Tube
 
ASTM A214/A214M
Standard Specification for Electric-Resistance-Welded Carbon Steel Heat-Exchanger and Condenser Tube
ASTM A214 Heat-Exchanger and Condenser Tube sizes usually furnished to this specification are to 3 in. [76.2 mm] in outside diameter, inclusive. 
 
ASTM A214 Heat-Exchanger and Condenser Tube Quick Details
Company Name: beite steel pipe
Country/Region: China
Product Name:ASTM A214 Heat-Exchanger and Condenser Tube
Manufacturing process: electric-resistance welding.
Outside Diameter:76.2mm
Wall thickness:0.4mm——12.7mm
Length:6000mm、12000m or specified length as required. 
 
Package: Bundles (hexagonal),Wooden Boxes,Crates (steel/wooden)
Port of Shipment:Tianjin,China
Payment:L/C or T/T
Delivery: 7-15 days after payment
Package:Standard export package,suit for all kinds of transport, or as required
Certificate:ISO 9001-2000,PED 97/23/EC,ASME,DNV

 
Manufacture
ASTM A214 Heat-Exchanger and Condenser Tubes shall be made by electric-resistance welding.
 
Heat Treatment
After welding, all tubes shall be heat treated at a temperature of 1650°F [900°C] or higher and followed by cooling in air or in the cooling chamber of a controlled atmosphere furnace. Cold drawn tubes shall be heat treated after the final cold-draw pass at a temperature of 1200°F [650°C] or higher.
 
Chemical Composition
Carbon, max % 0.18
Manganese, % 0.27 to 0.63
Phosphorus, max, % 0.035
Sulfur, max, % 0.035
 
Hardness Requirements
The tubes shall have a hardness number not exceeding 72 HRB.
Mechanical property requirements do not apply to tubing smaller than 1 ⁄ 8 in. [3.2 mm] in inside diameter or 0.015 in. [0.4 mm] in thickness.
 
Mechanical Tests Required
  • Flattening Test—One flattening test shall be made on specimens from each of two tubes from each lot or fraction thereof.
  • Flange Test—One flange test shall be made on specimens from each of two tubes from each lot  or fraction thereof.
  • Reverse Flattening Test—One reverse flattening test shall be made on a specimen from each 1500 ft [450 m] of finished tubing.
  • Hardness Test—Brinell or Rockwell hardness tests shall be made on specimens from two tubes from each lot.
  • Hydrostatic or Nondestructive Electric Test—Each tube shall be subjected to either the hydrostatic or the nondestructive electric test. The purchaser may specify which test is to be used.
 
Ordering Information
1 Orders for material under this specification should include the following, as required, to describe the desired material adequately:
1.1 Quantity (feet, metres, or number of lengths),
1.2 Name of material (electric-resistance-welded tubes),
1.3 Size (outside diameter and minimum wall thickness),
1.4 Length (specific or random),
1.5 Test report required (see Certification Section of Specification A 450/A 450M),
3.1.6 Specification designation, and
3.1.7 Special requirements.

Product key description, this is a very good product description, detailing our product use, product characteristics